Auxiliary pumps and valves table
The Bosch auxiliary pumps and valves are suitable for different applications, with a simple and easy installation design. In a voltage range between 12 V and 24 V, our products are also available with flow rate control via PWM. Our auxiliary pumps and valves are designed for operating mode S1 (continuous operation). These products are typically used in auxiliary cooling circuits.
Pumps
| Product family | Part number | Medium | 
				
					Nominal voltage (V)  | 
				
				
			
				
					
				
					Weight (kg)  | 
				
				
			
				
					
				
					Nominal pump  pressure (bar)  | 
				
				
			
				
					
				
					Flow rate (l/h)  | 
				
				
			
				
					Control | 
|---|---|---|---|---|---|---|---|
| Product family | Part number | 
					
						Medium
					
					 
						Water/Glycol
					 
				 | 
			
				
					
						Nominal voltage (V) 
						12
					 
				 | 
			
				
					
						Weight (kg) 
						0,33
					 
				 | 
			
				
					
						Nominal pump  pressure (bar) 
						0,2
					 
				 | 
			
				
					
						Flow rate (l/h) 
						500
					 
				 | 
			
				
					
						Control
					
					 
						PWM
					 
				 | 
			
				
| Product family | Part number | 
					
						Medium
					
					 
						Water/Glycol 
				Water/Glycol Water only  | 
			
				
					
						Nominal voltage (V) 
						12 
				12 12  | 
			
				
					
						Weight (kg) 
						0,65 
				0,66 0,55  | 
			
				
					
						Nominal pump  pressure (bar) 
						0,6 
				0,85 0,5  | 
			
				
					
						Flow rate (l/h) 
						1200 
				1000 950  | 
			
				
					
						Control
					
					 
						PWM 
				PWM PWM  | 
			
				
| Product family | Part number | 
					
						Medium
					
					 
						Water/Glycol 
				Water/Glycol  | 
			
				
					
						Nominal voltage (V) 
						12 
				12  | 
			
				
					
						Weight (kg) 
						0,46 
				0,46  | 
			
				
					
						Nominal pump  pressure (bar) 
						0,65 
				0,94  | 
			
				
					
						Flow rate (l/h) 
						1200 
				1000  | 
			
				
					
						Control
					
					 
						PWM 
				PWM  | 
			
				
| Product family | Part number | 
					
						Medium
					
					 
						Water/Glycol
					 
				 | 
			
				
					
						Nominal voltage (V) 
						12
					 
				 | 
			
				
					
						Weight (kg) 
						0,7
					 
				 | 
			
				
					
						Nominal pump  pressure (bar) 
						1,7
					 
				 | 
			
				
					
						Flow rate (l/h) 
						1,7
					 
				 | 
			
				
					
						Control
					
					 
						PWM
					 
				 | 
			
				
Solenoid valves
| Type of valve | Part number | Medium | 
				
					Nominal voltage  (V)  | 
				
				
			
				
					
				
					Flow rate (l/h)  | 
				
				
			
				
					
				
					Switchable pressure difference (kPa)  | 
				
				
			
				
					
				
					Pressure drop (kPa)  | 
				
				
			
				
|---|---|---|---|---|---|---|
| Type of valve | Part number | 
					
						Medium
					
					 
						Water/Glycol
					 
				 | 
			
				
					
						Nominal voltage  (V) 
						12
					 
				 | 
			
				
					
						Flow rate (l/h) 
						1500
					 
				 | 
			
				
					
						Switchable pressure difference (kPa) 
						150
					 
				 | 
			
				
					
						Pressure drop (kPa) 
						35
					 
				 | 
			
				
| Type of valve | Part number | 
					
						Medium
					
					 
						Water/Glycol 
				Water/Glycol Water/Glycol Water/Glycol  | 
			
				
					
						Nominal voltage  (V) 
						12 
				12 12 12  | 
			
				
					
						Flow rate (l/h) 
						1500 
				1500 1500 1500  | 
			
				
					
						Switchable pressure difference (kPa) 
						160 
				160 160 100  | 
			
				
					
						Pressure drop (kPa) 
						45 
				45 45 35  | 
			
				
Pumps
| Product family | Part number | Medium | 
				
					Nominal voltage (V)  | 
				
				
			
				
					
				
					Weight (kg)  | 
				
				
			
				
					
				
					Nominal pump  pressure (bar)  | 
				
				
			
				
					
				
					Flow rate (l/h)  | 
				
				
			
				
					Control | 
|---|---|---|---|---|---|---|---|
| Product family | Part number | 
					
						Medium
					
					 
						Water/Glycol
					 
				 | 
			
				
					
						Nominal voltage (V) 
						24
					 
				 | 
			
				
					
						Weight (kg) 
						0.67 
				 | 
			
				
					
						Nominal pump  pressure (bar) 
						0.6
					 
				 | 
			
				
					
						Flow rate (l/h) 
						1200
					 
				 | 
			
				
					
						Control
					
					 
						PWM
					 
				 | 
			
				
Solenoid valves
| Type of valve | Part number | Medium | 
				
					Nominal voltage  (V)  | 
				
				
			
				
					
				
					Flow rate (l/h)  | 
				
				
			
				
					
				
					Switchable pressure difference (kPa)  | 
				
				
			
				
					
				
					Pressure drop (kPa)  | 
				
				
			
				
|---|---|---|---|---|---|---|
| Type of valve | Part number | 
					
						Medium
					
					 
						Water/Glycol 
				Water/Glycol  | 
			
				
					
						Nominal voltage  (V) 
						24 
				24  | 
			
				
					
						Flow rate (l/h) 
						1500 
				1500  | 
			
				
					
						Switchable pressure difference (kPa) 
						150 
				150  | 
			
				
					
						Pressure drop (kPa) 
						35 
				35  | 
			
				
| Type of valve | Part number | 
					
						Medium
					
					 
						Water/Glycol 
				Water/Glycol  | 
			
				
					
						Nominal voltage  (V) 
						24 
				24  | 
			
				
					
						Flow rate (l/h) 
						1500 
				1500  | 
			
				
					
						Switchable pressure difference (kPa) 
						160 
				160  | 
			
				
					
						Pressure drop (kPa) 
						45 
				45  | 
			
				
Get in touch with us!